OBDLink EX [STN2232] ChangeLog
OBD Solutions LLC


v5.12.2 - 2025/10/30
--------------------

- BUG: Fixed an issue where CAN multi-frame message transmission would cause the device to lock up after 35 minutes of uptime



v5.12.1 - 2025/10/16
--------------------

- NEW: Added the Batched Commands feature, which supports sending multiple commands/requests in a single prompt
- NEW: Added the STBC command for enabling and disabling the Batched Commands feature
- NEW: Added the STBCOF command, which sets the output format for batched commands
- NEW: Added an optional parameter to STM and STMA commands to exit monitoring after reaching the specified message count
- NEW: Added the STITW command to set ISO protocol W timings

- CHG: STCSTM now also sets ISO 11898 inter-frame delay for segmented messages

- BUG: Fixed handling of ATCRA, ATCF, and ATCM so their values are preserved when ATSP or ATTP are issued, matching ELM327 behavior
- BUG: Fixed rare issue where an overflow condition could reduce message delay times
- BUG: Fixed rare ISO 15765 flow-control frame transmission failure during concurrent multi-frame reception
- BUG: Fixed INTERNAL ERROR when receiving more multi-frame messages than specified
- BUG: Fixed ATCRA not restoring default filters when used without a parameter
- BUG: Fixed bug, STPX now properly sends 29-bit CAN messages when the AT/ST protocol is configured to 11-bit CAN



v5.10.3 - 2024/02/01
--------------------

- NEW: Added the STIP command to set message parity for ISO-14230 protocols
- NEW: Added the STIIAP command to set initialization address parity for ISO-14230 protocols

- CHG: Changed STIFI command to keep ISO-14230 connection open post-initialization

- BUG: Fixed command prompt printing when using STSLEEP without specifying a delay
- BUG: Fixed user input validation for STPPMA
- BUG: Fixed an INTERNAL ERROR when the periodic message protocol doesn't match the current protocol



v5.9.5 - 2023/06/13
-------------------

- Initial release